Installation guide

Table 6 - 15. Media Ethernet Link Alarm Information
Alarm Name
Alarm
ID
Alarm Severity Cause(s)
Example Log
Message
Graphic Display Message
LINK UP ALARM
10GI
GPORT
131073 MINOR 10GbE S0P0 link
up
Slot 0 port 0 UP X LINK ALARMS (where X is num-
ber of alarming links)
LINK DOWN ALARM
10GI
GPORT
131075 MAJOR 10GbE S0P0 link
down
Slot 0 port 0 DOWN X LINK ALARMS
LINK UP ALARM
10GI
GPORT
131109 MINOR 10GbE S0P1 link
up
Slot 0 port 1 UP X LINK ALARMS
LINK DOWN ALARM
10GI
GPORT
131111 MAJOR 10GbE S0P1 link
down
Slot 0 port 1 DOWN X LINK ALARMS
Acme Packet 6100 Hardware Installation and Maintenance Guide 107
Management Ethernet
Link Alarms
The following table lists the NIU management Ethernet port alarms.
Table 6 - 16. Management Ethernet Link Alarm Information
Alarm Name
Alarm
ID
Alarm Severity Cause(s)
Example Log
Mess
age
Graphic Display Message
LINK UP ALARM
VXINTF
131077 MINOR Mgmt0 link up Port 0 UP X LINK ALARMS (where X is num-
ber of alarming links)
LINK UP ALARM
VXINTF
131078 MINOR Mgmt1 link up Port 1 UP X LINK ALARMS
LINK UP ALARM
VXINTF
131079 MINOR Mgmt2 link up Port 2 UP X LINK ALARMS
LINK DOWN ALARM
VXINTF
131080 MAJOR Mgmt0 link down Port 0 DOWN X LINK ALARMS
LINK DOWN ALARM
VXINTF
131081 MAJOR Mgmt1 link down Port 1 DOWN X LINK ALARMS
LINK DOWN ALARM
VXINTF
131082 MAJOR Mgmt2 link down Port 2 DOWN X LINK ALARMS
SFP Presence Alarms The following table lists the alarms that reflect when an SFP module is inserted
or removed from an NIU.
Table 6 - 17. SFP Presence Alarm Information
Alarm Name
Alarm
ID
Alarm Severity Cause(s) Example Log Message
Graphic Display
Mes
sage
SFP REMOVED GIGPORT 0 65568 CRITICAL S0P0 SFP Removed Slot 0 Port 0 SFP
Re
moved
SFP INSERTED GIGPORT 0 65564 CRITICAL S0P0 SFP Inserted Slot 0 Port 0 SFP Inserted