Installing the Chassis
in the Rack
Perform the reverse of the operations in the Physical System Removal section of this
document.
Please refer to earlier sections of this document for full rack installation procedures.
Validating the SSD Oracle recommends that you validate the Solid State Drive installation by running
Acme Packet 1100 diagnostics. All versions from nnCX_diags110.gz and later
include the appropriate tests for validating the SSD. Please refer to the diagnostics
documentation for more information.
In the following procedure, after booting into diagnostics, this preliminary check
ensures that the system recognizes the Solid State Drive.
Password: ******
-> dc
/boot/ - Volume is OK
243 MB
/code/ - Volume is OK
245 MB
/sata/ - Drive Present
476940 MB
Starting Diagnostic Executive...
Comm Express MCH 945 Present.
AHCI Support is Enabled.
Acme Packet Net-Net 6100
Diagnostic Executive Version 1.10
Creation date: Nov 25 2014 11:08:02
Board Level Diagnostics
Date & Time: TUE NOV 25 14:56:01 2014
[diag_proc] ->
Formatting the SSD After installing the Solid State Drive, you must format it. Details on file system
designs and the formatting procedure may be found in Chapter 9, File System
Maintenance of the Maintenance and Troubleshooting Guide for your software
release.