Quick Installation Guide

4
2.2 Mount Sensor unit onto Astro-Brac
2.2.1 Mount the SU to the Astro-Brac using the provided 2x M10 bolts,
locking washers and nuts.
2.2.2 Do not fully lock screws, until aiming phase is completed.
2.2.3 On the V2X Sensor Unit, attach two provided Surge Suppressors,
and on them attach two provided antennas. Use two provide
ground cables to ground Surge Suppressors to two ground studs
on bottom chassis. Then ground one of the studs to a well-
grounded connection on the traffic pole itself, or inside the
luminaire. Verify that the V2X antennas are firmly installed.
Powering the V2X module without properly connecting BOTH
antennas will cause permanent damage to the unit.
2.2.4 While mounting, note that the camera is facing in the direction of
the upcoming traffic. On the bottom back side of the Sensor Units
there is the back compartment, which holds the AC inlet, fuse, and
RJ45 maintenance port (hidden behind closed gland).
Ground studs
Surge Suppressor
Ground cable
Back compartment