User`s manual

INSTALLATION
~ 6 ~
2.3 H
ARDWARE
I
NSTALLATION
Step 1
Set the DIP-switch for Auto-scan Interval and BANK Address. If you have only one
KVM08, use the MASTER bank setting. If the KVM -08 you are using will be
Daisy-Chained off another unit, use a unique slave setting. Please refer to the previous
section for more information. NOTE: “ON” is down
DIP-Switch NO.
DIP-Switch NO.
1 2
Auto-scan Interval
3 4 5 6
BANK Address
ON ON 7 seconds ON ON ON ON BANK 0 MASTER
ON OFF 15 seconds OFF ON ON ON BANK 1 SLAVE
OFF ON 30 seconds ON OFF ON ON BANK 2 SLAVE
OFF OFF 60 seconds OFF OFF ON ON BANK 3 SLAVE
ON ON OFF ON BANK 4 SLAVE
OFF ON OFF ON BANK 5 SLAVE
ON OFF OFF ON BANK 6 SLAVE
OFF OFF OFF ON BANK 7 SLAVE
ON ON ON OFF BANK 8 SLAVE
OFF ON ON OFF BANK 9 SLAVE
ON OFF ON OFF BANK A SLAVE
OFF OFF ON OFF BANK B SLAVE
ON ON OFF OFF BANK C SLAVE
OFF ON OFF OFF BANK D SLAVE
ON OFF OFF OFF BANK E SLAVE
OFF OFF OFF OFF BANK F SLAVE
WARNING!
Before attempting to connect anything to the
KVM
08 or the computers, make sure everything is
powered off. Otherwise, plugging and unplugging
cables may cause irreversible damage to your
computers and the KVM08.