INSTALLATION THROUGH A MASONRY CHIMNEY (SEE FIGURE
4)
Step 1- Position appliance: Locate the appliance in accordance with the appliance
manufacturer’s instructions and clearance specifications. Mark the center of the hole where
the pipe is to penetrate the masonry chimney.
Step 2- Prepare the wall opening: If the masonry chimney has an existing 6” terra cotta
thimble, please skip to step #3. It will be necessary to break out the masonry around the
location of the pipe center line mark to a diameter 6 inches.
Step 3- Attach the Masonry Adapter: Attach the interior side of the Masonry Adapter (N)
to the take-off on the existing liner components (O). Place the take-off through the hole in
the masonry chimney and attach the clamping band from the take-off around the body of the
pre-installed tee/flexible liner system. The Masonry Adapter should now be flush with the
exterior side of the chimney.
Step 4- Pipe Installation: Install a Stove Adapter (H) or Stove Adapter Tee (A) by first
applying high temperature sealant onto the appliance flue collar and then secure the Stove
Adapter with a minimum of (3) #8 x ½” self-drilling screws. Connect sections of pipe (B)
together using the band clamp located on the female side of the outer pipe. A 90 degree
elbow (M) will be utilized to turn the pipe into the horizontal position. An adjustable slip
section pipe can now be used to connect from the elbow to the Masonry Adapter (N).
INSTALLATION TO AN EXISTING 2100 FACTORY BUILT
CHIMNEY (SEE FIGURE 5)
This type of installation is for connecting SBI Venting Division Pellet Vent Pipe to an existing
ceiling supported 2100 insulated chimney.
Step 1- Inspection: Remove any existing connector pipe from the appliance to the
Universal Adapter that is already installed in the Support Box. Visually inspect the interior
of the existing 2100 insulated chimney components (Q) for cleanliness and structural
integrity. All creosote must be removed from the existing chimney prior to connecting the
pellet vent pipe.
Step 2- Install Adapter: Install the appropriate sized 2100 insulated chimney Adapter (P)
(5”, 6”, 7”, or 8”). The Chimney Adapter will be connected to the Universal Adapter by a
minimum of three #8 x ½” self-drilling screws.
Step 3- Pipe Installation: Install Stove Adapter (H) or Stove Adapter Tee (A) by first
applying high temperature sealant onto the appliance flue collar and then secure the Stove
Adapter with a minimum of (3) #8 x ½” self-drilling screws. Connect sections of pipe (B)
together using the band clamp located on the female side of the outer pipe. An Adjustable
Length Pipe (Slip Section) can now be used to connect from the last standard pipe to the
Universal adapter.