User's Manual

RAZOR
®
HD GEN III
1514
Reindexing Turret Caps
After the rifle and scope have been
zeroed in, the elevation and windage
dials should be reindexed to their
zero indicators. This will allow you to
accurately keep track of elevation
or windage corrections dialed on the
turrets in the field, and quickly return
to an original zero-point setting.
1. While holding the elevation/
windage turret cap firmly between
thumb and forefinger to prevent
any rotation, use the 2mm hex
wrench to loosen and remove the
central screw on top of dial.
2. Gently pull the turret dial straight
up and off the turret post, being
careful not to rotate the post.
3. Reinstall the turret dial, lining up
the “0” mark with indexing mark
on the scope body and replace
the central screw on top of dial.
4. Replace the turret cap.
MAINTENANCE
Cleaning
Your Vortex
®
riflescope requires very little routine maintenance other
than periodically cleaning the exterior lenses. The scope's exterior may
be cleaned by wiping with a soft, dry cloth. When cleaning the lenses,
be sure to use products that are specifically designed for use on coated
optical lenses.
Be sure to blow away any dust or grit on the lenses prior to wiping
the surfaces.
Using your breath, or a very small amount of water or pure alcohol,
can help remove stubborn things like dried water spots.
Lubrication
All components of the riflescope are permanently lubricated, so no
additional lubricant should be applied.
NOTE: Other than to remove the turret caps, do not attempt to
disassemble any components of the riflescope. Disassembling of
riflescope may void warranty.
Storage
If possible, avoid storing your scope in direct sunlight or any very hot
location for long periods of time.
Replacing the Battery:
1. Unscrew the outer cap with a coin.
2. Remove the CR2032 battery.
3. Replace with a new CR2032 battery.
Battery Cover
Reinstall the
cap, aligning
“0” mark.
Lift and
remove
turret cap.
Remove
the central
screw.