Extra Information
Reduction
valve
12
.
Remove
the
cover
of
the reduction
valve
and
check
to
make
sure that
the
spring
and
the
piston
are
faultless
.
If
there are
reasons
to
suspect
a
fault
in
the
opening
pressure
of the
reduction
valve,
then
check
the
data
of
the spring
.
See
under
"Technical
Data"
-
reduction valve
.
Feed-pump
13
.
Depress
the
pump
lever
.
if
the
diaphragm
of the
pump
sounds
squeaky,
the
diaphragm
is
faultless
.
Changing
the
diaphragm
14
.
Remove
the
six
screws, holding
the
upper
and
lower
pump
housings
together
.
Remove
the
pump
lever
spring
(1)
and
remove
the
screw
(2)
holding
the
pump
lever
shaft
.
15
.
Use
a
suitable
pair
of
pliers
and
removethe
pump
lever
shaft
.
Pull
out
the
lever
and
the
diaphragm
.