Technical data

23
1. Battery
2. Main switch
3. Starter
4. Circuit breaker 50 A
5a. Connector, 2-pole male
5b. Connector, 2-poe female
6. Hydraulic pump
7. Connector with rubber cap, 3-pole
8a. Fully cast connectors, 3-pole female
8b. Fully cast connectors, 3-pole male
9a. Connector with rubber cap, 1-pole male
9b. Connector with rubber cap, 1-pole female
10a. Trim sender, digital
10b. Trim sender, analouge
11. Connector, 7-pole
12. Extension cable, Y-connector
13. Control panel
14. Triminstrument, analouge
15. Instrument lightning
16. Connecting terminal, instrument lightning (+) to main panel
17. Connecting terminal, fuse box (–) to main panel
18. Connecting terminal, fuse box (+) to main panel
19. Circuit breaker 10 A
20. Circuit breaker 10 A*
Power Trim SX without trim limiter (early production)
* Only certain executions of SX-C1, SX-CLT1, SX-C1AC,
SX-R1 and SX-R2
Cable color
BL = Blue P = Pink
LBL = Light-blue PU = Purple
BN = Brown R = Red
LBN = Light-brown SB = Black
GN = Green VO = Violet
GR = Gray W = White
OR = Orange Y = Yellow
Cable areas in (mm
2
) are given after the cable color codes.
Cable areas in brackets are AWG (American Wiring Gauge).
Conversion table:
mm
2
AWG
0.5 20
0.75 18
1.0 17
1.5 15–16
mm
2
AWG
2.5 13
610
10 7
A broken line indicates a non-Volvo Penta cable.