Product specifications
MASTERVOLT SOLAR SUNMASTER QS SERIES
TECHNICAL SPECIFICATIONS
SUNMASTER QS SERIES
12
General
Model Sunmaster QS 1200 QS 2000 QS 3200 QS 5000
Typical string length 5-9 72 cells modules or 10-18 36 cells modules
Operating temperature 0°C to 50°C
Storage temperature -20°C to 70°C
Relative humidity max. 95%; PCB has anti-moisture coating
Protection degree IP23
Noise level <30 dBA
Safety class class I
Galvanic isolation class II
Dimensions 330x220x111 mm 330x300x111 mm 435x318x144 mm 600x318x170 mm
Weight 4.4 kg 6 kg 10 kg 13 kg
Solar input (DC)
Nominal power 850W DC@40°C 1500W DC@40°C 2500W DC@40°C 3750W DC@40°C
PV power range 700-1200 Wp 1200-2000 Wp 2000-3400 Wp 3400-5000 Wp
MPP Tracker 1 MPP Tracker 2 MPP Trackers 3 MPP Trackers
MPP voltage range 100-380V DC; p-, m- and a-Si
Maximum voltage 450V DC
Nom. rated current@40°C 5A 7.5A 2x 7.5A or 1x15A* 3x 7.5A or 1x 22.5A*
Start-up power 2W, power drawn from the solar side 2W, power drawn from the solar side 4W, power drawn from the solar side 5W, power drawn from the solar side
String connections 2 2 2x2 or 1x4* 3x2 or 1x6*
DC connector glands + PCB spring terminals 4 mm
2
max. or Multi Contact connectors, depending on the model
Grid output (AC)
Voltage 230V (window settings and reclosure time depend on model, please refer to the delivery program on page 14 & 15)
Current (fused) 6.3A 10A 16A 25A
Frequency 50 Hz (window settings and reclosure time depend on model, please refer to the delivery program on page 14 & 15)
Power factor 0.99
THD < 3% @ rated load; in compliance with IEEE p929
Stand-by power 0W (DC voltage controlled relais)
European efficiency 92% 92% 93% 93%
Maximum efficiency 93% 93% 94% 94%
AC connector gland with PCB spring terminals; Europlug connector optional
Safety devices
General galvanic separation between DC and AC side, by means of a class II HF transformer
Island protection redundant voltage and frequency window monitoring (QNS); redundant switch off (independent control of 2 pole relais
and solid state switch); or ENS (VDE0126 compliant), depending on the model
Temperature protection power derating at higher ambient temperatures; switch off at 80ºC inverter temperature
DC side earth fault detection; over voltage, over current, transients (therm. guarded varistors), over power (temp. controlled derating),
reverse polarity protected
AC side over current (fuses), transients (varistors)
Compliance
CE/KEMA approval yes/pending
EMC directive EMC 89/336/EEG
Emission EN 50081-1, EN 55014, EN 55022, VDE 0871 class B
Harmonics EN 61000-3-2, IEEEp929
Immunity EN 50082-2
LV directive LV 73/23/EEC
Electric safety EN 60950 / KEMA approval pending
Monitoring
Indicator 6 LEDS for indication of power and fault diagnosis
External communication insert module for RS485 communication with the QS Data Bus (refer to page 6 & 7)
Available data UDC; IDC; PDC; UAC; IAC; PAC; FAC; temp; EAC (kWh: class II); total operating hours; status with fault indication
Available set points MPPTracker settings; QS Data Bus ID; U/F window settings; reset EAC counter
Monitoring devices The QS products can be linked using the QS Data Bus and connected to an extensive range of communication devices,
facilitating direct or remote communication through a telephone line, GSM network or wireless transmissions.
Display facilities and data monitoring capabilities (including external pulse inputs and analogue signals) are included
in the program. Please refer to page 6 & 7 for more information and to page 14 & 15 for the availability.