Owner`s manual

VANNER
Incorporated OWNER’S MANUAL
PMEC-12/24 OWNER‟S MANUAL
21
Wire Size and Temperature Rating
Cables connecting the PMEC to the batteries should be sufficiently sized to prevent unwanted voltage
drop. Vanner recommends the voltage drop should be no greater than 0.5 between the PMEC‟s +12/24
volt terminal and the battery +12/24 volt terminal. In most installations, the PMEC’s terminals should be
wired directly to the battery terminals (reference fault protection) to prevent voltage drop that could occur
in switch contacts, connections, and long wire runs. Since the PMEC can be operated in temperatures up
to 60ºC, use wire rated at least 90ºC. See the Wire and Fuse Size Chart below.
PMEC Wire and Fuse Size Chart
Wire
Size
AWG
Ring Terminal
AMP or UL
recognized
equal
Max wire length, in feet, between PMEC and battery to keep voltage drop under 0.5 volts.
The chart assumes wire carries no other load and wire temperature is below 80ºC.
PMEC-12/24
#4
33470
15.9
#2
322870
25.7
#1
321867
31.6
Fuse Designation
Current Rating
Vanner Part #
Fuse
Vanner Part #
Fuse Holder
Fuse F1
125 Amp
013912
013780
Fuse F2
*
*
*
Fuse F3
*
*
*
* Note: Fuse F2 and Fuse F3 are dependent on the current rating of the equalizer. Please contact