Owner`s manual

VANNER
Incorporated OWNER’S MANUAL
PMEC-12/24 OWNER‟S MANUAL
16
PMEC-12/24 Remote Input/Output Definitions
Remote Pin Assignments
Pin
Description
1
+5V
2
Ground
3
Switch Enable
4
Spare
5
Switch Disable
6
Auto-Start Enable
7
Engine Start
8
Fast Idle
Remote Functionality
The PMEC remote serves as a status indicator in addition to allowing the user to enable auto start
functionality. The auto start feature is enabled by simultaneously pressing and holding the two
“Enable” buttons, approximately three seconds, on the left side of the remote. When the auto start
feature is enabled, the “Autostart” LED will turn on.
The “Engine Start” LED turns on when the “Engine Start” signal is received from the PMEC.
The “Fast Idle” LED turns on when the “Fast Idle” signal is received from the PMEC.
The auto start feature is disabled by simply pressing the “Off” button on the right side of the remote.
The green “Autostart” LED will turn off.
The following are conditional inputs that will also disable the auto start feature;
1. Inserting key in ignition (if key sense option is present)
2. Ignition on
3. Moving transmission out of park
4. Opening the hood
Autostart
Fast Idle
Engine Start
Off
Enable
3 2 1
568 7
4
Connector on Rear
of Remote
Tyco 1-794065-0
Mating Connector:
Tyco 770579-1
Mating Contacts:
Tyco 171639-1