Datasheet

number 4 to number 7 of Infor3
when at MAX/MIN mode, REC character always display
REC 1 display REC , 0 doesn’t display REC
MAX 1 display MAX 0 doesn’t display MAX
MIN 1 display MIN 0 doesn’t display MIN
AV G 1 display AVG 0 doesnt display AVG
Number 0 to number 2 of Infor3
character 1 first line of LCD doesn’t display content 0 first line of LCD display content
----- 1 first line of LCD display ----- 0 first line of LCD doesn’t display -----
REC 1 first line of LCD doesn’t display REC 0 first line of LCD doesn’t display REC ( when it display REC, means enter Recall mode )
Infor4 7 6 5 4 3 2 1 0
byte secondline secondline secondline secondline secondline thirdline thirdline thirdline
character OL -OL ERR ----- character ------ FU
Number 4 to number 7 of Infor4