e) Data Logger "FILLUP"/"ENDLESS"
Here, you can set how the memory of the "Gamma Check Pro" is to be used.
• When "lling up" ("FILLuP"), data are saved until all memory is used up. When the memory is full, no further data
can be saved.
• For "Endless" ("EndLES"), the recording will run in an endless loop. When the memory is full, the respective oldest
data will be overwritten (ring memory).
• No data are saved at "OFF".
f) Data Logger "DATA"
Here, the data can be deleted ("CLR dAtA"). The entire contents of the memory are deleted.
The bar display at the lower edge of the display shows utilisation of the data memory.
g) Reset
This menu item deletes all measured values and returns the device to the delivery condition. This can be done, e.g.,
when the device is to be passed on to someone else.
If you conrm the reset process with the "OK" button (4); the reset is performed at once, without another prompt.