● 0x13 : Read Store Data Amount
PC to Meter
Start 0 Start 1 Control Data Length Checksum
0x55 0x55 0x13 0x00 0xBD
Meter to PC
Start 0 Start 1 Control
Data
Length
Data Checksum
0x55 0x55 0x13 0x02 See Below 0x??
Data Byte[0, 1] : Store data amount
● 0x18 : Command meter to Enter Download mode
PC to Meter
Start 0 Start 1 Control Data Length Checksum
0x55 0x55 0x18 0x00 0xC2
Meter to PC
Start 0 Start 1 Control Data Length Checksum
0x55 0x55 0x20 0x00 0xCA
● 0x19 : Command meter to Exit Download mode
PC to Meter
Start 0 Start 1 Control Data Length Checksum
0x55 0x55 0x19 0x00 0xC3
Meter to PC
Start 0 Start 1 Control Data Length Checksum
0x55 0x55 0x20 0x00 0xCA