Direct current
Range Accuracy Resolution
600 μA ±(0.3 % + 10 digits) 0.01 μA
6000 μA
±(0.5 % + 10 digits)
0.1 μA
60 mA 0.001 mA
600mA 0.01 mA
10 A ±(1.5 % + 20 digits) 0.001 A
Overload protection: Fuses; measuring time limit >5 A: max. 10 s with 10 min break
Alternating current
Range Resolution Accuracy Frequency range
600 µA 0.01 μA
±(0.6 % + 40 digits) 45 Hz - 1 kHz
±(1.2 % + 40 digits) 1 kHz - 10 kHz
6000 μA 0.1 μA
±(0.6 % + 40 digits) 45 Hz - 1 kHz
±(1.2 % + 40 digits) 1 kHz - 10 kHz
60 mA 0.001 mA
±(0.6 % + 40 digits) 45 Hz - 1 kHz
±(1.2 % + 40 digits) 1 kHz - 10 kHz
600 mA 0.01 mA
±(0.6 % + 40 digits) 45 Hz - 1 kHz
±(1.2 % + 40 digits) 1 kHz - 10 kHz
10 A 0.001 A
±(2 % + 40 digits)
45 Hz - 1 kHz
±(4 % + 40 digits) 1 kHz - 10 kHz
Overload protection: Fuses; measuring time limit >5 A: max. 10 s with 10 min break;
Overload protection: 1000 V; TrueRMS in the measuring range of 10 – 100 %
Impedance
Range Accuracy Resolution
600 Ω ±(1.0 % + 10 digits) with REL function 0.01 Ω
6 kΩ
±(0.6 % + 10 digits)
0.0001 kΩ
60 kΩ 0.001 kΩ
600 kΩ 0.01 kΩ
6 MΩ ±(1.2 % + 10 digits) 0.0001 MΩ
60 MΩ ±(2 % + 5 digits) 0.001 MΩ
Overload protection: 1000 V