Datasheet

Direct current
Range Accuracy Resolution
400 μA ±(0,3% +10) 0,01 μA
4000μA
±(0,5% +10)
0,1 μA
40 mA 0,001 mA
400 mA 0,01 mA
10 A ±(1,5% + 20) 0,001 A
Overload protection: Fuses, measuring time limit >5 A: max. 10 s with 10 min break
Alternating current
Range Accuracy Resolution Frequenz range
400 μA 0,01 μA
±(0,6 % + 40) 45 Hz - 1 kHz
±(1,2 % + 40) 1 kHz - 10 kHz
4000 μA 0,1 μA
±(0,6 % + 40) 45 Hz - 1 kHz
±(1,2 % + 40) 1 kHz - 10 kHz
40 mA 0,001 mA
±(0,6 % + 40) 45 Hz - 1 kHz
±(1,2 % + 40) 1 kHz - 10 kHz
400 mA 0,01 mA
±(0,6 % + 40) 45 Hz - 1 kHz
±(1,2 % + 40) 1 kHz - 10 kHz
10 A 0,001 A
±(2 % + 40) 45 Hz - 1 kHz
±(4 % + 40) 1 kHz - 10 kHz
Overload protection: Fuses, measuring time limit >5 A: max. 10 s with 10 min break
Overload protection 1000 V
TrueRMS in the measuring range of 10 – 100%
Measuring function AC + DC voltage
Range Accuracy Resolution Frequenz range
4 V 0,0001 V
±(1 % + 80) 45 Hz - 1 kHz
±(3 % + 40) 1 kHz - 10 kHz
±(6 % + 40) 10 kHz - 35 kHz
40 V 0,001 V
±(1 % + 80) 45 Hz - 1 kHz
±(3 % + 40) 1 kHz - 10 kHz
±(6 % + 40) 10 kHz - 35 kHz
400 V 0,01 V
±(1 % + 80) 45 Hz - 1 kHz
Not specified 1 kHz - 10 kHz
Not specified 10 kHz - 35 kHz
1000 V 0,1 V
±(1,2 % + 80) 45 Hz - 1 kHz
Not specified 1 kHz - 10 kHz
Not specified 10 kHz - 35 kHz
Overload protection 1000 V; Impedance: 10 MΩ