Datasheet
TECHNICAL DATA
Symbol Max. 40000 counts (characters)
Measuring rate approx. 2-3 measurements/second, Bargraf approx.
10 measurements/second
Measuring line length approx. 90 cm each
Measuring impedance >10MΩ (V range)
Operating voltage 9V block battery
Working conditions 0 to 30°C (<75%rF), >30 to 40°C (<50%rF)
Operating altitude max. 2,000 m
Storage temperature -10°C to +50°C
Weight approx. 380 g
Dimensions (LxWxH) 185 x 91 x 43 (mm)
Over-voltage category CAT III 1,000 V, CAT IV 600 V, contamination degree 2
Measurement tolerances
Statement of accuracy in ± (% of reading + display error in counts (= number of smallest points)). The accuracy is valid
for one year at a temperature of +23°C ± 5°C, and at a relative humidity of less than 75 %, non-condensing.
Temperature coefficient: +0.1 x (specified accuracy)/1°C
Direct voltage
Range Accuracy Resolution
400 mV ±(0,03% + 10) 0,01 mV
4 V
±(0,05% + 10)
0,0001 V
40 V 0,001 V
400 V 0,01 V
1000 V 0,1 V
Overload protection 1000 V; Impedance: 10 MΩ
Alternating voltage
Range Accuracy Resolution Frequenz range
4 V 0,0001 V
±(0,5 % + 40) 45 Hz - 1kHz
±(1,2 % + 40) 1 kHz - 10 kHz
±(3 % + 40) 10 kHz - 20 kHz
±(4 % + 40) 20 kHz - 100 kHz
40 V 0,001 V
±(0,5 % + 40) 45 Hz - 1kHz
±(1,2 % + 40) 1 kHz - 10 kHz
±(3 % + 40) 10 kHz - 20 kHz
±(6 % + 40) 20 kHz - 100 kHz
400 V 0,01 V
±(0,5 % + 40) 45 Hz - 1kHz
±(1,2 % + 40) 1 kHz - 10 kHz
±(3 % + 40) 10 kHz - 20 kHz
Not specified 20 kHz - 100 kHz
1000 V 0,1 V
±(1,2 % + 40) 45 Hz - 1kHz
±(3 % + 40) 1 kHz - 5 kHz
±(6 % + 40) 5 kHz - 10 kHz
Not specified 10 kHz - 100 kHz
Overload protection 1000 V; Impedance: 10 MΩ
TrueRMS in the measuring range of 10 – 100%: Crest factor: max. 3.0 (at 750V max. 1.5)