Capacity
Range Accuracy Resolution:
40 nF 0.01 nF
400 nF ±(3.0% + 5) with REL function 0.1 nF
4 µF 0.001 µF
40 µF ±(3,0% + 5) 0.01 µF
400 µF ±(4,0% + 5) 0.1 µF
4000 µF Not specified 1 µF
Overload protection 1,000V
Frequency/Duty cycle
Range Accuracy Resolution:
10 Hz to 10 MHz ±(0,1% + 3) 0.001 Hz to 0.01 MHz
0,1 – 99,9 % Not specified 0,1 %
Overload protection 750V
Sensitivity: 200 mV; Amplitude max. 5 Veff (>5 V with adjustable impedance)
Temperature (VC850 only)
Range Accuracy* Resolution:
-40 to -20 °C -(8,0% + 5)
-20 to 0 °C ±(1,2% + 4)
1 °C
0 to 100 °C ±(1,2% + 3)
100 to 1,000 °C ±(2,5% + 2)
* without sensor tolerance
Diode test
Test voltage Resolution:
Approx. 3.7 V 0.001 V
Overload protection: 1,000 V
Acoustic continuity tester <30 Ω continuous sound, test voltage: approx. 0.65 V/DC;
Overload protection 1,000 V
Do not exceed the maximum permitted input values. Do not touch any circuits or
parts of circuits if they can have higher voltages than 25 V Acrms or 35 V DC.
Danger to life!