Datasheet
Capacity
Range Accuracy Resolution
40 nF ±(2.5 % + 20 digits) 0.001 nF
400 nF
±(2.0 % + 20 digits)
0.01 nF
4 µF 0.0001 µF
40 µF 0.001 µF
400 µF 0.01 µ F
4000 µF ±(2.5 % + 20 digits) 0.1 µF
Frequency
Range Accuracy Resolution
40 Hz
±(0.02 % + 8 digits)
0.001 Hz
400 Hz 0.01 Hz
4 kHz 0.0001 kHz
40 kHz 1 Hz
400 kHz 10 Hz
4 MHz 0.0001 MHz
40 MHz 0.001 MHz
400 MHz N/A 0.01 MHz
Overload protection: 1000 V;
Sensitivity (10 Hz – 10 MHz): 200 mV; Amplitude max. 30 Veff (ms)
Sensitivity (10 MHz – 40 MHz): 600 mV; Amplitude max. 30 Veff (ms)
Sensitivity (>40 MHz); N/A
PACKAGE CONTENT
Multimeter // Power Cord // 1 kit measurement leads // 1 kit alligator clips // K type thermo couple // Software CD //
Operating instructions
This data sheet is published by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data processing systems
require the prior written approval by the editor. Reprinting, also in part, is prohibited. This data sheet represents the technical status at the time of printing.
© Copyright 2014 by Conrad Electronic SE. V2_0914_02-ETS-Mkde