Instructions

TECHNICAL DATA
Voltage range ........................................................ 12 - 1000 V/AC, 12 - 1200 V/DC
Frequency range ................................................... 0Hz;16-400Hz
LCD resolution ....................................................... +/- 12, 24, 50, 120, 230, 400, 600, 1200 V
Measurement tolerance for voltage check ............. +/-(3%+5digit)
DC/AC voltage recognition .................................... automatic
Auto-Power-On ...................................................... >12 V (DC/AC)
Response time ....................................................... <1 s
Resistance range ................................................... 0 - 1999 Ohm
Resistance measurement response time .............. <2 s at 25 °C
Times of controlled reduction
(Thermal protection voltage/time) .......................... 400 V/30s, 600 V/10s, 1000 V/5s
Max measurement time (RCD test) ....................... 30 s
Regeneration time (RCD test) ............................... 240 s
Max. test current ( RCD test) ................................ 30 mA/230V
Max. Current without RCD burden ....................... <6 mA/1200 V
Measurement category .......................................... CAT IV 600 V / CAT III 1000 V
Norms .................................................................... EN 60529 and EN 61243-3:2014
Kind of protection ................................................... IP64
Level of contamination ........................................... 2
Temperature range ................................................ -15 °C to +45 °C
Humidity ................................................................. max.85%relativehumidity,notcondensing
Altitude over sea level ........................................... max. 2000 m
Length of measurement cable ............................... ca. 93 cm
Current supply ....................................................... 2 type AAA/Micro batteries
Weight ................................................................... 130 g
Dimensions ............................................................ 67x205x27mm(BxHxT)
CONTINUITY TEST
Indication opticandacoustic(<400kΩ+/-50%)
Test current <5 uA
Overvoltage protection 1000 V/AC / 1200 V/DC
ThisisapublicationbyConradElectronicSE,Klaus-Conrad-Str.1,D-92240Hirschau(www.conrad.com).
Allrightsincludingtranslationreserved.Reproductionbyanymethod(e.g.photocopying,microlming,orthecapturein
electronic data processing systems) requires prior written approval from the editor. Reprinting, also in part, is prohibited.
This publication represents the technical status at the time of printing.
Copyright 2019 by Conrad Electronic SE. *1377526_V5_1019_hk_02_m