© Copyright 2014 by Conrad Electronic SE. V1_1014_02-ETS-Mkde
Measuring tolerances CLA40 probe converter
Measuring range 0.5 - 40 A
Resolution 0.01 A
Tolerance ± (2% + 5)
Output 10 mV/A
Frequency range 50/60 Hz
Probe opening 20 mm
DC zero offset settings ± 30 mV
DC zero basic deviation ± 0.050 A
AC zero basic deviation 0.100 A (max.)
Voltage supply 2 x micro batteries (AAA, R03)
Measuring cable length Max. 1.2 m
Dimensions 197 x 50 x 25 mm (L x W x H)
Weight 160 g
PACKAGE CONTENT
Digital multimeter // Clip-on ammeter // 1 set of measurement lines // 2 x batteries type AAA // Operating instructions