Capacity
Range Accuracy Resolution
6.000 nF ±(5% + 10) 0.001 nF
60.00 nF
±(5% + 5)
0.01 nF
600.0 nF 0.1 nF
6.000 µF 0.001 µF
60.00 µF 0.01 µF
600.0 µF 0.1 µF
6.000 mF
±10%
0.001 mF
60.00 mF 0.01 mF
Overload protection: 600 V PTC
Accuracies specied <1 µF only with REL-function
Frequency/Pulse width
Range Accuracy Resolution
10 Hz - 9.999 MHz ±(0.1% + 5) 0.001 Hz to 0.001 MHz
0.1% - 99.9% Not specied 0.1%
Overload protection: 600 V PTC
Sensitivity:
≤100 kHz: 100 mVrms - 20 Vrms
>100 kHz to ≤1 MHz: 200 mVrms - 20 Vrms
>1 MHz to ≤5 MHz: 500 mVrms - 20 Vrms
>5 MHz to ≤10 MHz: 900 mVrms - 20 Vrms
Frequency range pulse width: ≤100 kHz
Temperature Measuring
Range Accuracy Resolution
-40 to +0 °C ±5%
1 °C+0 to +100 °C ±(1.2% + 4)
+100 to +1000 °C ±(2.5% + 4)
-40 to +32 °F ±6%
1 °F+32 to +212 °F ±(2.0% + 6)
+212 to +1832 °F ±(3.0% + 6)
Overload protection: 600 V PTC
Sensor input: Type K