g) Frequency/Duty ratio
Range Accuracy Resolution
9.999 Hz to 9.999 MHz ±(0.7 % reading +4 digits) 0.001 Hz 0.001 MHz
0.1 % to 99.9 % For reference only. 0.01 %
Input range: (DC level=0)
≤100 kHz: 200 mVrms ≤ Input amplitude ≤30 Vrms
>100 kHz to 1 MHz: 600mVrms ≤ Input amplitude≤30 Vrms
> 1 MHz: 1 Vrms ≤ Input amplitude ≤30 Vrms
Duty ratio %: Only for frequency ≤10 kHz, amplitude >1 Vrms
Duty ratio applies only to ≤10kHz measurements
Frequency ≤1 kHz duty ratio: 10.0 % to 95.0 %
Frequency >1 kHz duty ratio: 30.0 % to 70.0 %
h) Diode/continuity test
Position Resolution Indication
0.1 Ω Acoustic continuity test: ≥150 Ω
resistance: no beep sound
Acoustic continuity test: ≤10 Ω resistance:
continous beep sound
0.001 V Diode test voltage: 3.2 V
p-n junction voltage 0.5 to 0.8 V
Overload protection: 600 V / DC ; Overload protection: 600 V / AC
i) Temperature
Measurement range Accuracy Resolution
-40 to +1000 ºC
-40 to +0 ºC ±5
1 ºC>+0 to +600 ºC ±(1.5 % reading +5 digits)
>+600 to +1000 ºC ±(2 % reading +5 digits)
-40 to +1832 ºF
-40 to +32 ºF ±8
2 ºF>+32 to +990 ºF ±(2 % reading +8 digits)
>+990 to +1832 ºF ±(2.5 % reading +8 digits)
Overload protection: 600 V / DC ; Overload protection: 600 V / AC
K-type thermo sensor 230˚C/446˚F
j) Non-contact voltage test
Target voltage: 230 V/AC