Datasheet

AC current (only with VC170-1), overload protection 1A/250V + 10 A/250 V, Average recording for sinus signal.
Range (40 - 400 hz) Accuracy Resolution
400 µA
±(1.6 % + 5)
0.1 µA
4,000 µA 1 µA
40 mA
±(2.0 % + 8)
0.01 mA
400 mA 0.1 mA
4 A
±(2.6 % + 4)
0.001 A
10 A 0.01 A
Resistance, overload protection 250 V, test voltage ca. 0.5 V
Range
VC130-1/150-1
Accuracy Resolution Range VC170-1 Accuracy Resolution
200 Ω
±(1.0 % + 10)
0.1 Ω 400 Ω ±(1.6 % + 3) 0,1 Ω
2000 Ω 1 Ω 4 kΩ
±(1.3 % + 2)
0.001 kΩ
20 kΩ 0.01 kΩ 40 kΩ 0.01 kΩ
200 kΩ 0.1 kΩ 400 kΩ 0.1 kΩ
20 MΩ ±(1.3 % + 7) 0.01 MΩ 4 / 40 MΩ ±(2.0 % + 8) 0.001 / 0.01 MΩ
Temperature (only VC150-1)
Range Accuracy Resolution
-40 to 0 °C ±(10.4 % + 7)
1 °C>0 to 400 °C
±(3.3 % + 4)
>400 to 1,000 °C ±(3.9 % + 4)
Frequency / duty cycle (only VC170-1)
Range Accuracy Resolution
10 Hz - 10 MHz
max. 10 Vrms
±(0.7 % + 4)
0.01 Hz - 0.01 MHz
Sensitivity:
< 100 kHz = 300 mV
> 100 kHz = 600 mV
0.1 – 99.9 % 0.1%
Acoustic continuity tester <10 Ω Permanent sound
Diode test test voltage Uo 3.0 V
Diode overload protection/continuity tester: 250 V
Transistor test “hFE” 0 – 1000ß, test voltage Uce 3 V, test current Ibo 10 µA
NCV voltage test 230 V/AC
PACKAGE CONTENT
Digital multimeter // Measurement lines // K type thermosensor // Battery // Operating instructions
This data sheet is published by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data processing systems
require the prior written approval by the editor. Reprinting, also in part, is prohibited. This data sheet represents the technical status at the time of printing.
© Copyright 2014 by Conrad Electronic SE. V2_0914_02-ETS-Mkde