Datasheet
TECHNICAL DATA
Display 2000 counts (4000 counts with the VC170-1)
Measuring frequency approx. 2-3 measuring operations/second
Measuring lead length about 75 cm each
Measuring impedance >10MΩ (V range)
Operating voltage 9 V block battery
Working conditions 0°C to 40°C max. 75% rF, non-condensing
Operating altitude max. 2,000 m
Storage temperature -10°C to +50°C
Weight ca. 200 g
Dimensions (LxWxH) 137 x 72 x 35 (mm)
Measuring category CAT III 250 V
Degree of contamination 2
Direct voltage, overload protection 250 V
Range
VC130-1/150-1
Accuracy Resolution Range
VC170-1
Accuracy Resolution
200 mV
±(0.5 % + 8)
0.1 mV 400 mV* ±(0.8 % + 8) 0.1 mV
2000 mV 1 mV 4000 mV
±(0.8 % + 8)
1 mV
20 V 0.01 V 40 V 0.01 V
200 V 0.1 V 250 V 0.1 V
250 V ±(0.8 % + 8) 1 V
* With the VC170-1, the 400 mV measuring range is only
available via the manual measuring range selection.
AC voltage (40 – 400 Hz), overload protection 250 V, Average recording for sinus signal.
Range
VC130-1/150-1
Accuracy Resolution Range VC170-
1
Accuracy Resolution
200 V
±(1.5% + 8)
0.1 V 400 mV* ±(2.0 % + 10) 0.1 mV
250 V 1 V 4,000 mV
±(1.6 % + 4)
1 mV
40 V 0.01 V
250 V 0.1 V
* With the VC170-1, the 400 mV measuring range is only
available via the manual measuring range selection.
DC current, overload protection 1A/250V + 10 A/250 V
Range
VC130-1/150-1
Accuracy Resolution Range
VC170-1
Accuracy Resolution
200 µA*
±(1.3 % + 2)
0.1 µA 400 µA
±(1.3 % + 2)
0.1 µA
2000 µA 1 µA 4,000 µA 1 µA
20 mA 0.01 mA 40 mA
±(1.6 % + 2)
0.01 mA
200 mA ±(1.5 % + 8) 0.1 mA 400 mA 0.1 mA
10 A ±(2.5 % + 10) 0.01 A 4 A
±(2.0 % + 10)
0.01 A
* only with the VC130-1 10 A 0.1 A