Datasheet

TECHNICAL DATA
Display 4000 digits
Auto-Power OFF
A signal sounds after approx. 15 minutes and the device shuts
down after another minute.
Measuring lead length Approx. 35 cm each
Input resistance >7.5 MΩ
Operating voltage 3V (2 x LR44)
Operating temperature 0°C to 40°C
Storage temperature -10°C to 50°C
Mass Approx. 108 g
Dimensions (LxWxH) 158 x 59 x 22 (mm)
Direct voltage range, overload protection 600 V
Range Accuracy Resolution
400 mV ±(0.8 % + 3 dgt) 0.1 mV
4 V
±(1 % + 3 dgt)
1 mV
40 V 10 mV
400 V 100 mV
600 V ±(1.2 % + 3 dgt) 1 V
Alternate voltage range, overload protection 600 V
Range (50 - 400 Hz) Accuracy Resolution
400 mV ±(1.8 % + 40 dgt) 0.1 mV
4 V
±(1.5 % + 4 dgt)
1 mV
40 V 10 mV
400 V 100 mV
600 V ±(1.5 % + 6 dgt) 1 V
Direct current range, overload protection 200 mA / 500 V
Range Accuracy Resolution
400 μA
±(1.5 % + 2 dgt)
0.1 μA
4 mA 1 μA
40 mA
±(1.8 % + 2 dgt)
10 μA
200 mA 100 μA
Alternate current range, overload protection 200 mA / 500 V
Range Accuracy Resolution
400 μA
±(2.0 % + 4 dgt)
0.1 μA
4 mA 1 μA
40 mA
±(2.2 % + 4 dgt)
10 μA
200 mA 100 μA