Instructions

52
b) LC display indication
Some settings are not indicated on the LC display. To check the settings, refer to chapter
“12h)Checkingthecongurationsettings”.
If there is not any display indicator or once the data logger starts/stops recording, the latest
measurement is shown on the display.
Mode Start mode Stop mode Remarks
1 No display indicator Not applicable TheredLED(2)asheswhenthememoryisfull.
2 No display indicator To stop the recording, press and hold down the
ENTER” button (8) for a few seconds.
3 No display indicator No display indicator
4 Not applicable TheredLED(2)asheswhenthememoryisfull.
To start the recording, press and hold down the
ENTER” button (8) for a few seconds.
5 To start and stop the recording, press and hold
downthe“ENTER” button (8) for a few seconds.
6 No display indicator To start the recording, press and hold down the
ENTER” button (8) for a few seconds.
7 Not applicable TheredLED(2)asheswhenthememoryisfull.
8 To stop the recording, press and hold down the
ENTER” button (8) for a few seconds.