Instructions
12
“System Setup” system settings
In the system menu, set general settings that the charger requires for operation. To enter the system menu, press and
hold down the knob for approx. 2 seconds. The system menu will be displayed with a beep.
The “System Setup” menu contains the following settings:
Menu item Meaning Value
Language System language English
MAX Input Power Set the maximum power of the voltage source to avoid
overload. The formula is: P = U x I. Power in W (P) =
voltage in V (U) x current in A (I).
450 W
(50 – 450 W in 10 W
increments)
MIN Input Voltage Set a low voltage level. This is useful when recharge-
able batteries are used as the power source. If the
value is below the lower limit, the charging/discharg-
ing process will be interrupted. This prevents deep
discharge of sensitive rechargeable battery types.
12.0 V
(9.0 – 24.0 V in 0.1 V
increments)
Capacity Cut Set the maximum capacity. If the set value is exceeded,
the charging/discharging process will be interrupted.
15000 mAh
(OFF)
100 - 50000 mAh in 100 mAh
increments)
Time Cut Set the maximum charging/discharge time. The timer
prevents innite charging in case of defective recharge-
able batteries.
180 min
(OFF 1 – 720 min in 1 min
increments)
Backlight Adjust the display brightness. Medium
(Low
Medium
High)
Volume Adjust the beep volume. High
(OFF
Low
Medium
High)
About Display the rmware and hardware version number.
Factory Reset Reset the device to factory settings. No
Yes
Back Ends the system setup and returns to the main display.
Turn the knob until the selection bar shows the menu item. Press the knob to conrm the selection. The menu item
will open.
Proceed with the selection of parameters shown. Follow the menu selection.