Programme settings
In the programme menu, you can pre-set all parameters for rechargeable battery care. To enter the programme
menu, briey press (for less than 1 second) the knob. The programme menu will be displayed with a beep (unless
the beep has been disabled in the system menu).
The “Programme” menu contains the following settings.
The values without brackets are pre-set, and the values in brackets describe the possible adjustment range.
Menu item Meaning Value
Battery Set the rechargeable battery type. LiPo
(LiPo, LiFe, Li-ion, LiHV, NiMH, NiCd,
Pb)
Cells Set the number of rechargeable battery cells
(S = cells).
LiPo 6S (1 - 6S)
LiFe 6S (1 - 6S)
LiIo 6S (1 - 6S)
LiHv 6S (1 - 6S)
NiMH Auto
NiCd Auto
Pb 6S (1 - 12S)
Mode Set the charging/discharge programme. Charge
(Charge
Discharge
Storage
Ext DISC)
Current Set the max. charge / discharge current. 2.0 A
(0.1-16.0 A in 0.1 A increments,
depending on the mode)
TVC Set the end-of-charge voltage per cell. LiPo 4.20 V (4.18 - 4.24 V)
LiFe 3.60 V (3.58 - 3.65 V)
LiIo 4.10 V (4.08 - 4.20 V)
LiHv 4.35 V (4.25 - 4.35 V)
NiMH 1.80 V
NiCd 1.80 V
Pb 2.40 (2.30 - 2.40 V)
Start Start the selected programme.
Back Ends the programme setup and returns to
the main display.
Follow the menu selection. Start with the rst menu item and then select all other menu items.