Instructions

Max continuous
power
+30dBm, average continuous power
Display Average Noise Level
(Input Attenuation= 0 dB, RBW=1Hz and RBW normalizes to 1Hz)
Preamp Off
1 MHz to 10 MHz
-130 dBm (Typical)
10 MHz to 1 GHz
-130 dBm (Typical)
1 GHz to 1.5 GHz
-128 dBm (Typical)
Preamp On
1 MHz to 10 MHz
-150 dBm (Typical)
10 MHz to 1 GHz
-150 dBm (Typical)
1 GHz to 1.5 GHz
-148 dBm (Typical)
Frequency response
(20 to 30, 30% to 70% relative humidity, input
attenuation=21 dB, reference frequency=50 MHz)
Preamp Off
±0.8 dB
±0.4 dB (Typical)
Preamp On
±0.9 dB
±0.5 dB (Typical)
Difference and Accuracy
RBW Switch
Difference
RBW=10kHz
Log resolution=±0.2 dB, Lin
resolution=±0.01. Nominal
Input Attenuation
Difference
20 ~30
, fc=50 MHz, Preamplifier Off,
21 dB RF attenuation, input signal 0~39 dB
±0.5 dB
Absolute Amplitude
Accuracy
20 to 30, fc=50 MHz, RBW=1 kHz,
VBW=1 kHz, peak detector, 21 dB RF
attenuation
Preamp Off
±0.4 dB, input signal level
-20 dBm
Preamp On
±0.5 dB, input signal level
-40 dBm