Instructions
5.11.2 [Track Gen On Off]
RF output and spectrum reception are fully synchronized on the
frequency sweep, and the tracking source frequency can not be set
individually.
5.11.3 [Output Level]
Tracking Source power output range from 0dBm to -30dBm.
5.11.4 [Network Meas►]
Tracking source network measurement function, mainly for
amplitude and frequency characteristics measurement; RF output
and spectrum measurement is fully synchronized, can be used as
a scalar network analyzer. When the network measurement
function is "on", the measurement results show relative values after
"normalized", expressed in "dB". When the network measurement
function is "off", the measurement shows the spectrum
measurement result, expressed in "dBm".
1) [Network Meas On Off]
Turn on or off the tracking source network measurement function.
Tracking source network measurement function, mainly for
amplitude and frequency characteristics measurement; RF output
and spectrum measurement is fully synchronized, can be used as
a scalar network analyzer. When the network measurement
function is "on", the measurement results show relative values after
"normalized", expressed in "dB". When the network measurement
function is "off", the measurement shows the spectrum
measurement result, expressed in "dBm".
2) [Output Level]
Used to set the output power of the trace source.
3) [Ref Level]
41