User manual
12
c) Program Settings
In the programme menu, you can preset all parameters for the rechargeable battery care. To enter the programme
menu, briey press (for less than 1 second) the knob. The programme menu will be displayed with a beep (unless the
beep has been disabled in the system menu).
The “Programme” menu contains the following settings.
The values without brackets are preset, and the values in brackets describe the possible adjustment range.
Menu item Meaning Value
Battery Here you can set the rechargeable battery
type.
LiPo
(LiPo, LiFe, Li-ion, LiHV, NiMH, NiCd, Pb)
Cells Here you can set the number of cells of the
rechargeable battery (S = cells).
LiPo 6S (1 – 6S)
LiFe 6S (1 – 6S)
Li-ion 6S (1 – 6S)
LiHV 6S (1 – 6S)
NiMH Auto
NiCd Auto
Pb 6S (1–12S)
Mode Here you can set the charging/discharge
programme.
Charge
(Charge
Discharge
Storage (store))
Current Here you can set the maximum charging
current.
2.0 A
(0.1 – 10.0 A in 0.1 A increments)
TVC Here you can set the end-of-charge voltage
per cell.
LiPo 4.20 V (4.18 – 4.24 V)
LiFe 3.60 V (3.58 – 3.65 V)
Li-ion 4.10 V (4.08 – 4.20 V)
LiHV 4.35 V (4.25 – 4.35 V)
NiMH 1.80 V
NiCd 1.80 V
Pb 2.40 (2.30 – 2.40 V)
Start Here you can start the selected programme.
Back Ends the programme setup and returns to
the main display.