Instructions
4.Advanced User Guidebook 
79 
The description of Pass/fail Menu is shown as the follows: 
Pass/Fail test: 
Detect whether the input signal is within the limits of the rule, if it exceeds limits of 
the rule, it is "Fail"; otherwise it is "Pass". Also it can output fail or pass signal by 
built-in and configurable output port. To run the test, read the following steps: 
1.  Push the Utility button, select Function in the bottom menu, select Pass/fail in the 
left menu. 
2.  Enable switch on: Select Operate in the bottom menu, select Enable in the right 
menu as ON. 
3.  Create rule: Select Rule in the bottom menu. Select Source in the right menu, 
select the source in the left menu. Set Horizontal tolerance and Vertical tolerance 
in the right menu. Select Create in the right menu to create the rule.   
4.  Set output type: Select Output in the bottom menu to enter output option setting. 
Choose any one or two of the options "Pass", "Fail" or "Beep". "Pass" and "Fail" 
are mutually exclusive options, which could not be chosen simultaneously. "Stop" 
means stop once the condition satisfies your setting. 
5.  Begin to test: Select  Operate  in the bottom menu, select Operate  in the right 
menu as Start, the test will begin. 
6.  Save rule: Select SaveRule in the bottom menu. Select the save location in the 
left menu, and then select Save in the right menu to save the rules, which could be 
called up at once when need. Select Load to call up the rule saved. 
Note:  
1.  When Pass/Fail is ON, if XY or FFT is ready to run, then Pass/Fail will be closed; 
under the mode of XY or FFT, Pass/Fail is unable. 
2.  Under the mode of Factory, Auto Scale and Auto Set, Pass/Fail will be closed. 
3.  When no save setting left in the rule save, tip will be given to show "NO RULE 
SAVED". 
Function Menu 
Setting 
Description 
operate 
Enable 
Operate 
Control enable switch 
Control operate switch 
Output 
Pass 
Fail 
Beep 
Stop 
Info 
Signal tested corresponds with the rule 
Signal tested not correspond with the rule 
Beep when it satisfies the rule  
Stop once satisfying the rule 
Control the display status of info frame 
Rule 
Source 
Horizontal 
Vertical 
Create 
Select source CH1, CH2 or Math 
Change the Horizontal tolerance value by turning the 
M knob 
Change the Vertical tolerance value by turning the M 
knob 
Use the rule set as testing rule 
SaveRule 
Number 
Save 
Load 
Select any one from Rule1 - Rule8 as your rule name 
Select Save to save the rule 
Load some rule as the testing rule 