Instructions
4.Advanced User Guidebook 
74 
(1)  Push Save button. 
(2)  Select  Type  in the bottom menu, in  the  left  menu, turn the  M  knob to select 
Clone. 
(3)  Select  Source  in the bottom menu, select  one channel (CH1/CH2)  or two 
channels (CH1&CH2) in the right menu for Source. 
(4)  Select Line in the bottom menu. If a or b is selected, turn the M knob to move the 
cursor.  If ab  is selected, turn the M  knob to move  the pair of cursors.  If  x  is 
selected,  the entire screen will be selected automatically.  The  waveform 
information is displayed at the left bottom corner of the screen. 
Length
Frequency
Time
Note: If "Out Of Limits" appears in the information or a message "Waveform 
points beyond the limit."  appears  on the screen, that means  the length of the 
cloned  waveform exceeds the limit.  When the source is CH1 or CH2, the 
maximum length is 2M; When the source is CH1&CH2, the maximum length is 
1M.  Push the Acquire  button, select Length  in the bottom menu,  and set the 
record length to a smaller value. 
(5)  Select Save in the bottom menu. 
  To save the waveform to internal memory, select Storage in the right menu 
as Internal. Turn the M knob to select an object in the left menu, select Save 
in the right menu. 
  To save the waveform onto a USB memory device, insert a USB memory 
device into the port on the front panel. If the icon   appears on the top right 
of the screen, the USB memory device  is installed successfully. If the USB 
memory device  cannot be recognized, format the USB memory device 
according to the methods in "USB disk Requirements" on P65. Select Storage 
in the right menu as External. Select Save  in the right menu. An  input 
keyboard used to edit the file name will pop up. The name is default as current 
system date and time. Turn the M knob to select the keys, push the knob to 
input. Select the   key in the keyboard to confirm. The cloned waveform 
will be saved onto the USB memory device as a file with the ota suffix. 
To output the cloned waveform in the internal memory through the generator: 
(The generator is optional.) 
(1)  Push Save button. 
(2)  Select  Type  in the bottom menu, in  the  left  menu, turn the  M  knob to select 
Clone. 
(3)  Select Save in the bottom menu, select Storage in the right menu as Internal. 
(4)  Turn the M knob to select an object in the left menu. If the source of the selected 
waveform is CH1 or CH2, select AG Output in the right menu and set the output 
channel of the generator. If the source is CH1&CH2, the output channel is not 