Instructions
4.Advanced User Guidebook 
52 
MENU 
SETTING 
INSTRUCTION 
Bus Type  CAN  Set vertical channel bus type as CAN trigger. 
Input 
Source 
CH1 
CH2 
Select CH1 as the trigger source. 
Select CH2 as the trigger source. 
Type 
CAN_H 
CAN_L 
TX 
RX 
Actual CAN_H bus signal. 
Actual CAN_L bus signal. 
Transmission signal on the CAN signal line. 
Received signal on the CAN signal line. 
Sample 
Point 
Turn the  M knob  (or tap on   in touchscreen) to set 
the Sample point, which is a point within a bit’s time. The 
oscilloscope samples the bit level at this point. “Sample 
point” is represented by the percentage of “the time from 
the start of the bit’s time to the sample point time” in the 
“bit’s time”. The range is 5% to 95%. 
Common 
Baud 
Turn the M knob to select from the Baud list on the left. 
Custom 
Baud 
Turn the  M knob  (or tap on   in touchscreen) to set 
the Baud. The range is 10,000 to 1,000,000. 
Tip: You can select the nearest value in Common Baud, 
and then adjust it in this menu. 
Condition 
Start 
Trigger on the start frame of the data frame. 
Type 
Type 
(Bottom 
menu)
Data 
Trigger on the selected frame. 
Remote 
Error 
Overload 
ID 
Configure 
(Bottom 
menu)
Format 
Select Standard or Extended. 
ID 
Use  the  M  knob  and Direction 
key on the front panel to set. 
Data 
Configure 
(Bottom 
menu)
Byte 
Length 
Set the number of bytes with the 
M knob. The range is 1 to 8. 
Data 
Set the data with the M knob 
and  Direction key on the front 
panel. 
ID&Data 
Configure 
(Bottom 
menu)
Format 
Select Standard or Extended. 
ID 
Use  the  M  knob  and Direction 
key on the front panel to set. 
Byte 
Length 
Set the number of bytes with the 
M knob. The range is 1 to 8. 