Instructions
4.Advanced User Guidebook 
45 
In Nth Edge Trigger mode, the trigger setting information is displayed on bottom right 
of the screen, for example,  ,indicates that trigger type is Nth 
Edge, trigger source is CH1, -150V is up level or low level threshold. 
Nth Edge Trigger 
Nth Edge Trigger menu list: 
MENU 
SETTING 
INSTRUCTION 
Single 
Mode 
Nth Edge  Set vertical channel trigger type as Nth Edge trigger. 
Source 
CH1 
CH2 
Select CH1 as the trigger source. 
Select CH2 as the trigger source. 
Edge 
Edge 
Trigger on the rising edge of the input signal when 
voltage level meets the specified trigger level. 
Trigger on the falling edge of the input signal when 
voltage level meets the specified trigger level.
Configure 
Idle Time 
Set idle time before the edge counting in Nth Edge 
Trigger. Adjust M knob or click   to set idle time 
press     panel button or click   to 
move cursor to choose which digit to be set. Available 
range is 30ns-10s, default 100ns. 
Edge Num 
Set the edge number value of “N” in Nth Edge trigger. 