the direct current bias. The operation steps are shown as below: 
(1) Push the CH1 button to show the CH1 SETUP menu. 
(2) Select Coupling in the bottom menu. 
(3) Select DC in the right menu. Both DC and AC components of the signal are passed.   
(4) Select AC in the right menu. The direct current component of the signal is blocked. 
2.  To adjust the probe attenuation 
For correct measurements, the attenuation coefficient settings in the operating menu of the 
Channel should always match what is on the probe (see "How to Set the Probe Attenuation 
Coefficient" on P12). If the attenuation coefficient of the probe is 1:1, the menu setting of 
the input channel should be set to X1. 
Take the Channel 1 as an example, the attenuation coefficient of the probe is 10:1, the 
operation steps are shown as follows: 
(1) Push the CH1 button to show the CH1 SETUP menu. 
(2) Select Probe in the bottom menu. Select Attenu in the right menu, turn the M knob to 
set it as 10×. 
3.  To measure current by probing the voltage drop across a resistor 
Take the Channel 1 as an example, if you are measuring current by probing the voltage 
drop across a 1Ω resistor, the operation steps are shown as follows: 
(1) Push the CH1 button to show CH1 SETUP menu. 
(2) Select Probe in the bottom menu. In the right menu, set MeasCurr as YES, the A/V 
radio menu will appear below. Select it; turn the M knob to set the Amps/Volts ratio. 
Amps/Volts ratio = 1/Resistor value. Here the A/V radio should be set to 1. 
4.  To invert a waveform 
Waveform inverted: the displayed signal is turned 180 degrees against the phase of the 
earth potential. 
Taking the Channel 1 for example, the operation steps are shown as follows: 
(1) Push the CH1 button to show the CH1 SETUP menu. 
(2) Select Inverted in the bottom menu, switch to ON. the waveform is inverted. Push 
again to switch to OFF, the waveform goes back to its original one. 
5.  To set bandwidth limit 
When high frequency components of a waveform are not important to its analysis, the 
bandwidth limit control can be used to reject frequencies above 20 MHz. 
Taking the Channel 1 for example, the operation steps are shown as below: 
(1) Push the CH1 button to show CH1 SETUP menu. 
(2) Select Limit in the bottom menu. 
(3) Select Full band in the right menu. The high frequency of the signal will be allowed 
to pass. 