Direct current (A/DC)
Range Resolution Accuracy
600.0 µA 0.1 µA
±(1.0% + 7)
6000 µA 1 µA
60.00 mA 0.01 mA
600.0 mA 0.1 mA
6.000 A 0.001 A ±(3.5% + 30)
60.00 A 0.01 A ±(3.5% + 5)
600 V overload protection
Fuses:µA/mA=self-resettingPTCfuse4x160mA,internalresistanceapprox.<10Ω
60 A transformer input: 10 mV/A, max. 600 mV, overload protection by PTC
Speciedmeasurementrangewithaclamptransformer:0.6-60A
The multimeter may display 3 counts when a measurement input is open
Alternating current (A/AC)
Range Resolution Accuracy
600.0 µA 0.1 µA
±(1.3% + 6)
6000 µA 1 µA
60.00 mA 0.01 mA
600.0 mA 0.1 mA
6.000 A 0.001 A ±(3.5% + 30)
60.00 A 0.01 A ±(3.5% + 5)
Overload protection 600 V; frequency range 45 - 400 Hz
Fuses:µA/mA=self-resettingPTCfuse4x160mA,internalresistanceapprox.<10Ω
60 A transformer input: 10 mV/A, max. 600 mV, overload protection by PTC
SpeciedmeasurementrangemA/µA:5-100%ofthemeasurementrange
Speciedmeasurementrangewithaclamptransformer:0.6-60A
The multimeter may display 3 counts when a measurement input is open
TrueRMSpeak(CrestFactor(CF))≤3CFovertheentirerange
TrueRMS peak for non-sinusoidal signals plus tolerance
CF >1.0 - 2.0 + 3%
CF >2.0 - 2.5 + 5%
CF >2.5 - 3.0 + 7%