User manual

69
Measuring tolerances
Accuracy in ± (% of reading + display error in counts (= number of smallest points)). These accuracy readings are
valid for one year at a temperature of +23 °C (± 5 °C) and a relative humidity of less than 75 % (non-condensing). If
themultimeterisusedoutsideofthistemperaturerange,usethefollowingcoefcienttocalculatetheaccuracy.+0.1x
(speciedaccuracy)/1°C
The accuracy of measurements may be affected when the multimeter is used in a high-frequency electromagnetic
eld.
Direct voltage (V/DC)
Range Resolution Accuracy
60.00 mV* 0.01 mV ±(1.2% + 8)
600.0 mV* 0.1 mV ±(1.0% + 8)
6.000 V 0.001 V
±(0.9% + 4)60.00 V 0.01 V
600.0 V 0.1 V
*Only available in “mV” mode
Speciedmeasurementrange:5-100%ofthemeasurementrange
600Voverloadprotection;Impedance:10MΩ(mV:≤1000MΩ)
Themultimetermaydisplay≤10countsifameasurementinputisshort-circuited.
Direct voltage (V/DC) LoZ
Range Resolution Accuracy
6.000 V 0.001 V
±(1.8% + 7)60.00 V 0.01 V
600.0 V 0.1 V
Speciedmeasurementrange:5-100%ofthemeasurementrange
600Voverloadprotection;Impedance:400kΩ(max.250V,3secs)
Themultimetermaydisplay≤10countsifameasurementinputisshort-circuited.
After using the LoZ feature, leave the multimeter for 1 minute before using it again.