User manual
68
14. Technical data
Multimeter VC281:
Display ..............................................................6000 Counts (digits)
Measuring rate ..................................................approx. 2 - 3 measurements/second
AC measurement method .................................True RMS, AC-coupled
Test lead length ................................................approx. 90 cm
Measuring impedance ......................................≥10MΩ/10pF(Vrange)
Measurement socket clearance ........................19 mm (COM-V)
Low battery indicator ........................................Batteryvoltage≤6V
“Dangerous voltage” indicator ..........................≥30V/AC-DC
“Range exceeded” alarm ..................................≥600V/AC-DC,>60A/AC-DC
“OL” (overload) alarm .......................................≥610V/AC-DC,≥60,10A/AC-DCormeasurement>6600counts
Automatic shut-off  ............................................after approx.15 minutes (can be manually disabled)
Current consumption (auto off) .........................<30 µA
Operating voltage .............................................9 V block battery
Operating conditions .........................................0 to +40 °C (<75% RH)
Operating altitude .............................................max. 2000 m above sea level
Storage temperature .........................................-10 °C to +50 °C
Weight ..............................................................approx. 375 g
Dimensions (L x W x H) ....................................178 x 85 x 40 mm
Measuring category ..........................................CAT III 600 V
Pollution degree ................................................2
Safety regulations  ............................................meets EN 61010-1
CLA60 clamp transformer:
Clamp opening .................................................25 mm
Maximum conductor diameter ..........................20 mm
Measurement function ......................................DC, AC True RMS
Output ...............................................................10 mV/A
Test lead length ................................................approx. 120 cm
Power supply voltage .......................................2x micro batteries
Operating conditions .........................................0 to +40 °C (<75% RH)
Operating altitude .............................................max. 2000 m above sea level
Storage temperature .........................................-10 °C to +50 °C
Weight ..............................................................approx. 184 g
Dimensions (L x W x H) ....................................195 x 50 x 29 mm
Measuring category ..........................................CAT III 600 V
Pollution degree ................................................2
Safety regulations  ............................................meets EN 61010-1