User manual

72
Alternating voltage (V/AC) LoZ
Range Resolution Accuracy
6.000 V 0.001 V
±(2.3% + 7)60.00 V 0.01 V
600.0 V* 0.1 V
Speciedmeasurementrange:5-100%ofthemeasurementrange
Frequencyrange:45-400Hz;Overloadprotection:600V;Impedance:400kΩ(*max.250V,3s)
The multimeter may display 10 counts if a measurement input is short-circuited
After using the LoZ feature, leave the multimeter for 1 minute before using it again
TrueRMSpeak(CrestFactor(CF))≤3CFto600V
TrueRMS peak for non-sinusoidal signals plus tolerance:
CF >1.0 - 2.0 + 3%
CF >2.0 - 2.5 + 5%
CF >2.5 - 3.0 + 7%
Direct current (A/DC)
Range Resolution Accuracy
600.0 µA 0.1 µA
±(1.0% + 7)
6000 µA 1 µA
60.00mA 0.01mA
600.0mA 0.1mA
6.000A 0.001A ±(1.3% + 4)
10.00A 0.01A ±(1.6% + 7)
Overload protection: 600 V
Fuses:µA/mA=self-resettingPTCfuse4x160mA,internalresistanceapprox.<10Ω
10 A = High-performance FF12AH1000V ceramic fuse
≤6A=continuousmeasurement,>6A=max.10satintervalsof15minutes
The multimeter may display 3 counts when a measurement input is open.