User manual
53
Proceed as follows to measure alternating “V ” (AC) voltages:
-   Switch the DMM on and select the “V ” measurement 
mode. 
-   Press the “SELECT” (I) button on the rotary control to switch to 
“AC” mode. “TRMS, “AC” and “V” will appear on the display. 
-   For lower voltages up to max. 600 mV, select the “mV ” 
measurement range. Press the “SELECT” (I) button on the 
rotary control to switch to “AC” mode. “TRMS”, “AC” and the 
unit “mV” will appear on the display.
-   Insert the red lead into the V socket (G) and the black lead into 
the COM socket (H).
-   Connect the two measuring probes to the object that you want 
to measure (e.g. generator or circuit).
-  The measurement will appear on the display.
-   After taking a measurement, remove the leads from the meas-
ured object and switch the DMM off.
 The“VDC/AC”voltagerangehasaninputresistanceof>10MΩ.ThemVrangehasaninputresistanceof
≤1000MΩ.Ifopenmeasuringinputsareused,anundenedmeasurementvaluemaybedisplayedinthe
mV range due to the high input resistance. This, however, has no effect on the measurement result.
d) LoZ voltage mode
LoZmodeallowsyoutomeasureDCandACvoltageswithalowimpedance(approx.400kΩ).Inthismode,the
multimeter lowers the internal resistance to prevent phantom voltage readings. As a result, the circuit is more heavily 
loaded than in the standard measuring mode.
InordertouseLoZmeasurementmode,pressthe“Lowimp.400kΩ”button(J)duringvoltagemeasurement.The
measured impedance is reduced for as long as the button is pressed.
“LoZ” (B20) will appear on the display.
  LoZ measurement mode may only be used up to a maximum voltage of 250 V. The duration of the LoZ 
measurement must be limited to a maximum of 3 s. This mode is not available in the mV measurement 
range.
  After using LoZ mode, leave the multimeter for 1 minute before using it again.