User manual
51
Follow the steps below to measure AC currents (A ):
-   Switch on the DMM and select “10A, mA, oder µA” mode. Press “SELECT” to switch to AC mode. “AC” will ap-
pear on the display. Pressing the “SELECT” button again to switch back to DC mode.
-   The table shows the different measuring modes and the corresponding measurement ranges. Select the desired 
measurement range and connect the corresponding terminals.
Measurement mode Measurement range Terminals
µA <4000 µA COM + mAµA
mA 4 mA – 399 mA COM + mAµA
10A 400 mA – 10 A COM + 10A
-   Insert the red lead into the mA µA or 10 A terminal. Plug the black test lead into the COM terminal.
-   Connect the two measuring probes in series to the object that you want to measure (e.g. battery or circuit). The 
electrical circuit must be disconnected before you connect the probes.
-   Reconnect the circuit. The measurement will appear on the display. 
-   After measuring, disconnect the circuit and remove the test leads from the measured object. Switch off the DMM.