c) AC + DC voltage
Range Resolution Accuracy
6.000 V 0.001 V
±(2 % + 6)
60.00 V 0.01 V
600.0 V 0.1 V
Frequency range 40 – 400 Hz; 600 V overload protection
Speciedmeasuringrange:5–100%ofthemeasuringrange
TrueRMSpeak(CrestFactor(CF))≤3CFto600V
TrueRMS peak for non-sinusoidal signals plus tolerance
CF >1.0 – 2.0 + 3 %
CF >2.0 – 2.5 + 5 %
CF >2.5 – 3.0 + 7 %
d) Direct current (µA/DC)
Range Resolution Accuracy
2000 µA 1 µA ±(0.9 % + 6)
600 V overload protection
Automatic current limitation with integrated PTR components.
e) Alternating current (µA/AC)
Range Resolution Accuracy
2000 µA 1 µA ±(1.5 % + 6)
Frequency range: 40–400 Hz; 600 V overload protection