Instructions

61
Alternating current (A/AC, clamp measurements)
Range Resolution Accuracy
40–100 Hz 100–400 Hz
A 60.00 A 0.01 A
±(1.8% + 8) ±(3.5% + 6)
600.0 A 0.1 A
Frequency range 40–400 Hz; 600 V overload protection
Speciedmeasuringrange:5–100%ofthemeasuringrange
The multimeter may display <2 counts when a measuring input is open
TrueRMSpeak(CrestFactor(CF))≤3CFto600V
TrueRMS peak for non-sinusoidal signals plus tolerance
CF >1.0 - 2.0 + 3%
CF >2.0 - 2.5 + 5%
CF >2.5 - 3.0 + 7%
Resistance
Range Resolution Accuracy
60.00Ω* 0.01Ω ±(1.5% + 3)
600.0Ω* 0.1Ω ±(1.2% + 3)
6.000KΩ 0.001KΩ
±(1.0% + 3)60.00KΩ 0.01KΩ
600.0KΩ 0.1KΩ
6.000MΩ 0.001MΩ ±(1.5% + 3)
60.00MΩ 0.01MΩ ±(2.5% + 6)
600 V overload protection
Measuringvoltage:Approx.-2.8V(60/600Ω-measuringrange),-1V(otherranges)
Measuring current: Approx. -1.4 mA
*Afterdiscountingtestleadresistance