User manual

22
BLOCK-DIAGRAMM10.
CH1(X)
EINGANG
CH1 ATT
CH1
VORVER -
STÄRKER
FUNKTIONS -
GENERATOR
CH1 TRIG
(X-ACHSE)
AUFNAHME-
VERSTÄRKER
VERT
SIGNAL
VERT MODUS-
SCHALTER
VERTIKALER
AUSGANGS -
VERSTÄRKER
CH2 (Y)
EINGANG
CH2 ATT
CH2
VORVER -
STÄRKER
SCHALTLOGIK
TRIG
SIGNAL
Z-ACH -
SEN-VER -
STÄRKER
CH2 TRIG
AUFNAHME-
VERSTÄRKER
CRT-SCHALT -
KREIS
Z-ACHSEN
EINGANG
H.V. VERSOR -
GUNG
X-ACHSEN SIGNAL
CH1
CH2
TRIG
SCHALTER
TRIG EIN -
GANGS-VER -
STÄRKER
TRIG
GENERATOR
AUTO
SCHALTKREIS
FREE RUN
SINGAL
(A) ABLEN -
KUNGS-GEN -
ERATOR
HORIZONTALE
SCHALTUNG
HORIZONTAL -
ER AUSGANGS -
VERSTÄRKER
EXT TRIG
EINGANG
EXT
NETZ
NETZ TRIG
FÜR JEDEN
BLOCK
2 Vp-p / 1 kHz
ENERGIEVER -
SORGUNG
KALIBRATOR
AC-NETZ
50/60 Hz
ENTSORGUNG11.
Im Interesse unserer Umwelt und um die verwendeten Rohstoffe möglichst vollständig zu
recyclen, ist der Verbraucher aufgefordert, gebrauchte und defekte Geräte zu den öffentlichen
Sammelstellen für Elektroschrott zu bringen.
Das Zeichen der durchgestrichenen Mülltonne mit Rädern bedeutet, dass dieses Produkt an
einer Sammelstelle für Elektronikschrott abgegeben werden muss, um es durch Recycling einer
bestmöglichen Rohstoffwiederverwertung zuzuführen.
31
Miscellaneous
Repair works must only be carried out by a specialist/ specialist workshop.
If you have queries about handling the device, that are not answered in this operating
instruction, our technical support is available under the following address and telephone
number: Voltcraft
®
, 92242 Hirschau, Lindenweg 15, Germany, phone 0180 / 586 582 7.
PRECAUTIONS BEFORE OPERATION6.
Unpacking the instrument
The product has been fully inspected and tested before shipping from the factory. Upon receiving the
instrument, please unpack and inspect it to check if there is any damage caused during transportation.
Checking the Line Voltage
The product can be applied any kind of the line voltage shown in the table below. Before connecting
the power plug to an AC line outlet, make sure the voltage selector of the rear panel is set to the correct
position corresponding to the line voltage. It might be damaged the instrument if connected to the wrong
AC line voltage.
To avoid electrical shock, the power cord protective grounding conductor must be
connected to ground.
The fuse must be changed following after the line voltage shown as below:
Line voltage Range Fuse
AC 115V 97~132V T 0.63A / 250V
AC 230V 195~250V T 0.315A / 250V
To avoid personal injury, disconnect the power cord before removing the fuse
holder.
Environment
The normal ambient temperature range of this instrument is from 0° to 40°C (32° to 104°F).
To operate the instrument over this speci c temperature range may cause damage to the circuits.
Do not operate the instrument in a place where strong magnetic or electric eld exists as it may disturb
the measurement.
Equipment Installation and Operation
Ensure there is proper ventilation for the vent of the instrument. If it is not according to the speci cation to
operate the instrument, the protection provided by the instrument may be impaired.