3.  INTENDED USE
-   Measuring and displaying electrical parameters in the measuring category CAT III up to max. 
600 V or CAT II up to max. 1000 V against ground potential in compliance with EN 61010-1 
and all lower categories. The multimeter may not be used in the measuring category CAT IV.
-  Direct and alternating current measurements up to max. 600 A (AC - True RMS)
-  DC and AC voltage measurements up to max. 1000 V/DC, 750 V/AC (AC - True RMS)
-  Temperature measurements from -40 to +1000 °C
- Resistancemeasurementsupto60MΩ
- Continuitycheck(<10Ωacoustic)
-  Diode test
-  Capacitance measurements up to 6 mF
- Non-contactACvoltagedetection(NCV)≥100-750V/ACand≤10mmdistance
-  Display of readings on Android or Apple iOS mobile device via Bluetooth®
A rotary switch is used to select the desired measuring function. Automatic range selection is 
active for all measuring functions (except temperature measurement, diode test and continuity 
test).
The VC-595OLED displays true RMS in both the alternating current and alternating voltage 
range. For negative values, the polarity is displayed automatically with the sign (-).
The multimeter features a folding current clamp for non-contact current measurement. There 
is no need to disconnect the circuit to be measured. The current clamp is also designed and 
approved for measuring non-insulated, dangerously live conductors. The voltage in the circuit 
to be measured may not exceed 1000 V in CAT II or 600 V in CAT III. It is recommended to 
wear personal protective equipment for measurements in the CAT III range. The multimeter 
may not be used in the CAT IV range.
The multimeter is operated with three commercially available 1.5 V micro batteries (type AAA, 
LR03).
Themultimetermaybeoperatedwiththespeciedbatterytypeonly.Batterieswithacell
voltage of 1.2 V may not be used. An automatic power-off function prevents premature battery 
drain. The automatic power-off function can be deactivated or set from 1 to 30 minutes in 1 