Proceed as follows to measure alternating currents (A  )
-   Turn on the DMM using the rotary switch (13) and select the measuring range „A 
„. The 
display shows „A“ and the symbol for alternating current „
„.
-   In the alternating current measuring range, the 
display is set to zero automatically when the 
clampisclosed.Ifastrongmagneticeldin
the vicinity is affecting the display, you can 
compensate this undesired display value using 
the REL function (relative value 
measurement).
-   Push the open lever (4) to open the current 
clamp.
-   Clamp the individual conductor to be 
measured and reclose the clamp. Position the 
conductor in the middle of the two triangular 
position symbols on the clamp.
-   The alternating current is shown in the large 
display, the frequency in the small display above it.
-   Remove the clamp from the measuring object and turn off the device after measurement. 
Turn the rotary switch to „OFF“.