User manual

43
Resistance
Range Accuracy Resolution
400.0 Ω ±(1.5 % + 6 Counts) 100 mΩ
4.000 kΩ ±(1.5 % + 2 Counts) 1 Ω
40.00 kΩ ±(1.5 % + 2 Counts) 10 Ω
400.0 kΩ ±(1.5 % + 2 Counts) 100 Ω
4.000 MΩ ±(2.5 % + 3 Counts) 1 kΩ
40.00 MΩ ±(3.5 % + 5 Counts) 10 kΩ
Capacitance
Range Accuracy Resolution
40.00 nF ±(6.0 % + 40 Counts) 0.01 nF
400.0 nF ±(4.0 % + 5 Counts) 0.1 nF
4.000 µF ±(3.5 % + 5 Counts) 1 nF
40.00 µF ±(3.5 % + 5 Counts) 10 nF
100.0 µF ±(6.0 % + 5 Counts) 100 nF
Frequency (sensitivity min. 10 Vrms, for 20 – 80 % duty cycle)
Range Accuracy Resolution
5.000 Hz ±(1.5 % + 7 Counts) 1 mHz
50.00 Hz ±(1.5 % + 2 Counts) 10 mHz
500.0 Hz ±(1.5 % + 2 Counts) 100 mHz
5.000 kHz ±(1.5 % + 2 Counts) 1 Hz
50.00 kHz ±(1.5 % + 2 Counts) 10 Hz
500.0 kHz ±(1.5 % + 2 Counts) 100 Hz
5.000 MHz ±(1.5 % + 2 Counts) 1 kHz
10.00 MHz ±(1.5 % + 2 Counts) 10 kHz