f) Resistance Measuring 
 Make sure that all circuit parts, circuits and components and other objects of 
measurement are disconnected from the voltage and discharged. 
Proceed as follows to measure resistance: 
-  Turn the DMM on and select the measuring function “Ω”. 
-  Plug the red measuring line into the Ω measuring jack (9) 
and the black measuring line into the COM measuring jack 
(8).
-  Check the measuring lines for continuity by connecting 
the two measuring prods. The impedance value must be 
approximately 0 to 1.5 Ohm (inherent impedance of the 
measuring lines). 
-  Now connect the two measuring prods to the object to be 
measured. As long as the object to be measured is not 
high-impedance or interrupted, the measured value will be 
indicated on the display. Wait until the displayed value has 
stabilised. With impedances of >1 MOhm, this may take a 
few seconds.
-  If “OL” (overload) appears on the display, you have 
exceeded the measuring range or the measuring circuit is 
interrupted. 
-  Remove the measuring lines from the object to be measured after completion of the meas-
urement and switch off the DMM.
   If you perform a resistance measurement, make sure that the measuring points you 
touch with the measuring prods are free of dirt, oil, solderable lacquer or similar. Such 
circumstances can falsify the measured result.